Description
|
15 = G1/2" |
|
20 = G3/4" |
|
25 = G1" |
|
35 = G1-1/4" |
|
40 = G1-1/2" |
|
50 = G2" |
|
62 = G2-1/2" |
|
75 = G3" |
|
76 = G3" |
|
89 = G3" |
|
102 = G4" |
|
Right angle |
Embedded |
Inline |
Plug |
|
|
Design-pressure |
0.3~0.8MPa |
0.2~0.8MPa |
0.3~0.8MPa |
0.2~1.0MPa |
|
Working-pressure |
0.3~0.6MPa |
0.2~0.6MPa |
0.3~0.6MPa |
0.2~0.6MPa |
|
Ambient Temperature |
-25~60℃ Customized for lower or higher temperature |
|||
|
Relative Humidity |
≤85% |
|||
|
Working Medium |
Clean Air |
|||
|
Voltage |
AC220V/DC24V/AC110V/AC24V Customized |
|||
|
Protection Class |
IP65 |
|||
|
Diaphragm Life |
Over One Million Cycles |
|||
|
Cv/Kv |
Call us for detail |
|||
Material Construction
|
Body
|
ADC12 die cast
|
|
Armature
|
430FR stainless steel
|
|
Diaphragm
|
Nitrile or viton
|
|
Spring
|
321 Stainless steel
|
|
Fasteners
|
302 Stainless steel
|
Common failure and troubleshooting
|
Use period |
Failure phenomena |
Possible Reason |
Troubleshooting |
|
During installation and commissioning |
The valves cannot all be opened, but the leading part does act. |
Check the gas dome pressure to see if it is too low. |
Check the leakage |
|
Some valves do not work, but the others are normal. |
Check the valve coil connection and coil |
Replace the accessories |
|
|
The valves cannot all be closed. There is leakage. There is no way to establish a gas dome. |
Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves. |
Check the leakage |
|
|
Z-valve. The valve inlet and blowing muzzle are installed backwards. |
Re-install |
||
|
Some valves cannot be closed. There is leakage. |
There is some dirt or debris on the membrane, ii is blocking the moving iron core. |
Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock. |
|
|
A valve closing is slowly. |
The membrane orifice is blocked. |
Dredge the membrane orifice |
|
|
During use period |
Some valves are leaking. The membrane cannot close tightly and the valve is always open a little. |
There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked. |
Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary. |
|
Coil is hot and burned out. |
It has been turned on for too long. |
Check the working condition of the control system. |
|
|
Voltage exists but the valve does not operate. |
Membrane is damaged and the orifice is blocked. |
Replace the accessories in time. |
|
|
Ambient temperature is below -20℃. The valve is leaking and cannot open. |
Ambient temperature is too low and here is frost in the valve. |
Pay attention to insulation and maintaining proper temperatures. |

Air filter bag for dust proof system
Stripe Anti Static Polyester Needle Felt Dust Bag Long Term Temperature Resistance
550g/M2 Polyester Needle Felt Air Filter Bag Flame Retardant Industrial Dust Bag
Polyester Mixed Conductive Fiber Needle Felt Dust Bag Industrial Air Filter Bag 550g/M2
Middle Temperature Needle Felt Dust Bag 700g/M2 Oilproof Air Filter Bag
Customized Polyester Spunlace Felt Dust Bag 550g/m2 Air Filter Bag
Acrylic Polyacrylonitrile PAN Needle Felt Dust Air Filter Bag Flame Retardant
Polyphenylene Sulfide Needle Felt Dust Bag Sanmin PPS Air Filter Bag
Expanded Glass Fiber Dust Bag Customized Air Filter Bag Valve Parts